I could edit the firmware but I like this just in case there are thermocouple issues.

I can also point a heat gun at it for a minute.

  • JohnEdwa@sopuli.xyz
    link
    fedilink
    English
    arrow-up
    8
    ·
    edit-2
    3 days ago

    You can check what the value actually would read as if you unplug the thermistor (as that’s what it’s a protection against), and as long as you aren’t near that reducing MINTEMP should be perfectly fine. For example, mine reports something like -50C.